Note |
Radiation Safety Management Vol.2, No.1 (29-32) |
|
Monte Carlo Calculation of External Dose Rate around a Radionuclide Reservoir Tank Using EGS4 |
Ichiro Yamaguchi1) and Hisateru Ohba2)
|
|
1) Department of Environmental Health, National Institute of Public Health
2) Radiation Safety Office, Sapporo Medical University Hospital
|
Received March 3, 2003; accepted September 3, 2003
|
A new method has been proposed for calculating the dose rate around a radioisotope reservoir tank using EGS4 (Electron Gamma Shower Version 4). Several improvements, such as uniform distribution of the radioactive substances in the reservoir tank and shielding effect by the tank wall, were made for more accurate determination of the activity-to-dose rate conversion coefficients. The Monte Carlo code EGS4 was employed in this report, and the cumulative dose around the reservoir tank was calculated. The results of calculations are useful for a design for radiation safety management in PET (positron emission tomography) facilities. |
Key words: |
Monte Carlo Method, EGS4, Radiation dose, Radioisotope reservoir tank |
|